Integrated Controls / A+CLASS
MASTER/ROW CONTROL SWITCH TID
A+CLASS
MASter/row ControL SwitCh
Technical Installation Data
© 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications
without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com
Page 1/2 Rev. 08/05/13 H72-00435
US Patent #8,436,542
Fig. M - Front of Master On/O Switch Fig. R - Front of Row On/O Switch
Fig. B - Back of Switch without cables
Example shown: Row 1 Switch
Description
The A+CLASS™ Master Control and Row Control Switches are designed to provide a user interface and on/o control of systems operating on
Class 2, low voltage circuitry. Master and/or Row Control Switches are provided as part of the A+CLASS™ system. See INCLUDED COMPONENTS
below for additional switch station component information. Congurations of A+CLASS™ Master and/or Row Control switches are provided
based on customer order.
speciFicAtions
• Electrical Ratings: Each switch: 100mA @ 30VDC Max
• Accepts standard decorator style wall plate, provided with A+CLASS™ system
• UL and cUL listed when installed as part of a complete A+Class™ System
• 5-year warranty when installed as part of a complete A+Class™ System
precAUtions
CAUTION: FOR USE WITH CLASS 2, LOW VOLTAGE SYSTEMS ONLY. DO NOT USE IN HIGH VOLTAGE APPLICATIONS.
• Read and understand all instructions before beginning installation.
• NOTICE: For installation by a licensed electrician in accordance with National and/or local Electrical Codes.
• NOTICE: For indoor use only.
CAUTION: USE COPPER CONDUCTOR ONLY.
• Conrm device ratings are suitable for application prior to installation. Use of device in applications beyond its specied ratings or in
applications other than its intended use may cause an unsafe condition and will void manufacturer’s warranty.
• NOTICE: Do not install if any damage to product is noticed.
• ALL EXCESS CAT5 CABLE MUST BE REMOVED FROM WALL BOX PRIOR TO INSTALLATION. Connection between CAT5 cable and switch
connection port must remain straight and true without interference or pressure from excess or misaligned cable.
incLUDeD coMponents
1. Classroom Control Module (CCM)
2. Switch Stations
• Master On/O: Turns all rows of lighting on or o from a single switch
• Row 1, Row 2, Row 3, Row 4: Turns one row of lighting on or o. Each row requires a separate switch. A+CLASS will support up to four
individual rows of lighting. Row controls are typically ganged together with only one home run back to the CCM per gang.
3. 50' Yellow CAT5 Cable
• One per Master On/O switch station
• One per Row single or ganged switch station
4. 3" Yellow CAT5 Jumper Cable (Row Gangs Only)
• Not required for Master On/O switch station
• One per each jump required
• 2-Row switch gang: 1 jumper
• 3-Row switch gang: 2 jumpers
• 4-Row switch gang: 3 jumpers
• If multiple Row stations are used, the appropriate number of jumpers will be provided
5. Switch Plate(s) for single or multi-gang as dictated by customer order
6. A+CLASS™ lighting xtures (shipped separately)